| Sign In | Join Free | My brakesband.com |
|
Brand Name : KACISE
Model Number : KTG111-C
Certification : CE
Place of Origin : CHINA
MOQ : 1PCS
Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability : 1000 Piece/Pieces per Week negotiable
Delivery Time : 5-8 work days
Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available
Measurement Range : 0.00 - 2.00%/25.0% (Optional measurement ranges)
Allowable Error : ±2%FS
Repeatability : ±1%FS
Resolution : 0.0001
Response Time : t90 ≤ 30s
Zero Drift : ≤±1%FS/7d
The product is widely used in on - line detection and analysis of hydrogen content in explosion - proof and non-explosion - proof scenarios during industrial production processes such as water electrolysis for hydrogen and oxygen production, fertilizers, petrochemicals, air separation, and biological fermentation.
This instrument uses a fuel - cell - type electrochemical sensor, usually composed of silver and lead electrodes immersed in an electrolyte. The measured gas diffuses through a gas - permeable membrane to the electrodes, where a chemical reaction occurs, enabling the measurement of oxygen content.
| Measurement Range | 0.00 - 2.00%/25.0% (Optional measurement ranges) |
|---|---|
| Allowable Error | ±2%FS |
| Repeatability | ±1%FS |
| Resolution | 0.01% |
| Response Time | t90 ≤ 30s |
| Zero Drift | ≤±1%FS/7d |
| Span Drift | ≤±1%FS/7d |
| Sample Gas Flow Rate | (300 ± 30) mL/min |
| Operating Power Supply | Transmitter 24VDC |
| Operating Environment | |
| Operating Temperature | - 15℃ - +45℃ |
| Operating Humidity | ≤90%RH |
| Overall Dimensions | 140mm (Width)×140mm (Height)×220mm (Depth) |
|---|---|
| Cutout Dimensions | 136mm (Width)×136mm (Height) |
| Parameters of External Safety Barrier | Vo ≤ 28VDC, Io ≤ 93mA, Cp ≤ 0.02uF, Lp ≤ 1mH |
| Weight | 1.8kg |
| Dimensions | 130mm*136mm |
|---|---|
| Analog Output | 4 - 20mA |
| Digital Output | RS458 interface, modbus protocol. |
| Explosion - proof Mark | Exd IIC T6 |
| Weight | 1.8kg |
|
|
KTG111-C Hydrogen and Oxygen Analyzer with ±1%FS Repeatability for Water Electrolysis and Fast Response Time ≤30s Images |